1000KW Biogas Generator
Advantage
1000KW biogas genset Jichai cooperated with WOODWARD Company, adopting an advanced international gas-fired external mixing method, using advanced electronic control technology and lean-burn control strategy to develop a gas engine with gas and air mixed before turbocharger, which is cost-effective and has good Controllability and reliability.
Production Characteristic
▪Production:H16V190,L12V200
▪100% independent intellectual property;
▪International mainstream control technology( engine intelligent management system);
▪International advanced air-gas ratio control technology(TECJECT air-fuel ratio automatic adjustment);
▪High flow and high pressure intake system adapts to wide variations in concentration (30% to 60% methane concentration);
▪Low pressure air-intake and lean combustion control technology ( adopt to low pressure gas, better emissions);
▪Advanced management module (automatic synchronization and automatic load distribution);
▪Online Maintenance Technology (More than 2500 hours of continuous trouble-free operation);
▪Digital Monitoring Technology (Full monitoring of engine thermal parameters and unit electrical parameters);
▪Distributed Energy Systems( Electric-Thermal, Electric-Hot-Cool)
Genset Model | 1000GF-Z | 1100GF-Z |
Alternator model | Brush-less Excitation, Automatic Voltage Regulation | |
Rated power | 1000kW | 1100kW |
Rated voltage | 400V/6300V/10500V/480V/13800V | |
Rated frequency | 50Hz/60Hz | |
Rated power factor | 0.8 | |
Protection class | IP23 | |
Insulation class | H | |
Engine Model | H16V190ZLZ-2 | L12V200ZLZ-2 |
Type | Four strokes, V-type, Turbocharged, Inter-cooling,Spark plug ignition | |
No. of cylinder | 16 | 12 |
Bore | 190mm | 200mm |
Stroke | 215mm | 255mm |
Total displacement | 97.53L | 96.1L |
Rated speed | 1000r/min,1200r/min | |
Rated power | 1200kW | |
Gas consumption | ≤9500kJ/kW.h | ≤9000kJ/kW.h |
Oil consumption | ≤0.6g/kW.h | ≤0.45g/kW.h |
Cooling type | Open type-cooling tower/Closed type-Vertical or Horizontal Radiator | |
Lubrication method | Pressure and splash lubrication | |
Starting method | Electric starting |
Application Case
Our Company
Our Factory